Showing posts with label Mainframes. Show all posts
Showing posts with label Mainframes. Show all posts

Monday, May 10, 2010

MVS SYSTEM CODES-S813

The data set name in the JCL did not match the data set name on the tape.

1. The JCL volume serial number was wrong.
2. The data set name in the JCL was misspelled.
3. The wrong tape was mounted.
4. The incorrect data set sequence number was specified in the label parameter.
5. The data set does not exist on the magnetic tape. Verify that the JCL is correct, and resubmit the job.

Ref: www.ibmmainframes.com

Sunday, May 02, 2010

MVS SYSTEM CODES-S913

An error occurred in opening a magnetic tape data set.

1. The error occurred during open or end-of-volume processing. The data set was password protected, and a correct password was not entered.

2. The error occurred in opening a checkpoint data set which was concatenated to a non-checkpoint data set.


1. Supply the correct password, and resubmit the job.

2. Eliminate any concatenations of checkpoint and non-checkpoint data sets.


Ref: www.ibmmainframes.com

Saturday, May 01, 2010

MVS SYSTEM CODES -SA13

An error occurred in opening a tape data set.

1. The file sequence number was wrong on a multi-volume tape data set.

2. The file sequence number was wrong, or it was less than that of the first data set on the tape.

3. The volume serial number was wrong.

4. The job which wrote the tape did not write all the data sets.

Steps:
1. Verify that the JCL is correct, and resubmit the job.

2. If the desired data set does not exist on the tape, recreate the tape.
Ref: www.ibmmainframes.com

Thursday, April 01, 2010

MVS SYSTEM CODES -SB37

An error occurred during end-of-volume processing of a data set. The system was unable to fulfill a request for more space.

1. A program loop caused too many records to be written to the output data set.
2. Insufficient space was allocated to this data set in the JCL.
3. There was no more room available to receive any more output on the output volume, and another volume could not be mounted.

1. Verify that there are no program loops or logic errors.
2. Increase the primary and/or secondary allocations for the data set.
3. Change the JCL to request that the data set be created on a volume with more space.

Ref: http://www.ibmmainframes.com/

Saturday, March 20, 2010

MVS SYSTEM CODES - SC13

An error occurred in opening a concatenated partitioned data set.
1. A concatenated data set was opened for output. 2. A data set was opened twice. Be sure that the concatenated partitioned data set is being opened properly.

Ref: www.ibmmainframes.com

Thursday, March 18, 2010

MVS SYSTEM CODES -SD37

An error occurred in writing to a data set which had not been allocated enough space. 1. A secondary allocation was not specified, and all of the primary space had been used. 2. There was a program loop.

1. Check through the program logic for a loop.
2. Allocate more space to the data set by specifying larger primary and/or secondary quantities in the space parameter in the JCL DD statement.

Ref: www.ibmmainframes.com

Tuesday, December 15, 2009

MVS SYSTEM CODES -S80A

The storage needed to execute the program was not available.
1. The region parameter did not specify enough storage.
2. The region parameter was omitted, and the default storage amount was too small to run the correct program.
3. Block sizes were increased or buffers were added, and the region size was not increased.
4. A logic error caused excessive storage to be obtained but not freed.

1. Increase the region size.
2. Look for logic errors which may cause excessive calls to other programs or requests for storage.

Ref: www.ibmmainframes.com

Saturday, November 28, 2009

MVS SYSTEM CODES-S804

The storage needed to execute the program was not available.

1. The region parameter did not specify enough storage.
2. The region parameter was omitted, and the default storage amount was too small to run the correct program.
3. Block sizes were increased or buffers were added, and the region size was not increased.
4. A logic error caused excessive storage to be obtained but not freed.

1. Increase the region size.
2. Look for logic errors which may cause excessive f calls to other programs or requests for storage.

Ref: www.ibmmainframes.com

Sunday, November 22, 2009

MVS SYSTEM CODES-S806

A module requested by the program could not be found.

1. The module requested did not exist in the data sets specified in the STEPLIB or JOBLIB.
2. A JCL STEPLIB or JOBLIB DD statement was missing or incorrect.
3. The module name was misspelled.
4. An I/O error occurred in searching for the module in the library directory.

1. Verify that the correct program is being requested.
2. Ensure that the appropriate STEPLIB or JOBLIB DD statements are in the JCL.
3. If necessary, recreate the data set.
Ref: www.ibmmainframes.com

Friday, October 09, 2009

MVS SYSTEM CODES-S713

An error occurred in opening a data set on tape. 1. An attempt was made to output to the data set, before the expiration date specified had been reached. 2. The incorrect volume was requested.

Ref: www.ibmmainframes.com

Monday, October 05, 2009

MVS SYSTEM CODES-S714

An error occurred in closing a tape data set. 1. An I/O error occurred while writing a trailer label or tapemark. Rerun the job specifying another volume or device.

Ref: www.ibmmainframes.com

Wednesday, September 23, 2009

Ingenium product Vs Mainframe Technology

Ingenium Knowledge
• Exposure to Domain and end to end knowledge of Policy Administration system
• Various Insurance Product Implementation / business processes exposure
• Specific Products knowledge is valued against technologies in the market
• Quick recognition and faster growth perspective
• Opportunity to play multiple roles and responsibilities based on experience and exposure

Open/Mainframe System Knowledge
• Limited to technology and not much exposure to domain
• Knowledge is restricted only towards technology / business process of that applications
• Niche technical skills alone are valued in the market
• Quick recognition and Growth perspective is not very encouraging
• Career Path is limited with pre-defined roles and responsibilities

Friday, July 24, 2009

MVS SYSTEM CODES -S237

An error occurred in end-of-volume processing of a magnetic tape data set.

Possible causes & Solution:
1. The block count of the tape label did not agree with that of the DCB. One or more blocks may have been skipped during processing.
2. An incorrect volume serial number was specified in the volume parameter of the DD statement.
3. An incorrect volume was mounted.
4. The DSN was misspelled.
1) Verify that the DSN is spelled correctly, and that the correct volume(s) are specified and mounted. Correct any errors, and resubmit the job.
2) If all the data set information appears correct, resubmit the job specifying a different device in the unit parameter of the JCL. If this does not correct the error, re-create the data set.

Ref: www.ibmmainframes.com

Wednesday, July 22, 2009

MVS SYSTEM CODES -S314

An input/output error occurred in closing a data set on a direct access device.
Possible causes: The volume or the device was defective.
Resolution: Rerun the job specifying another volume or device.

Ref: www.ibmmainframes.com

Wednesday, July 08, 2009

MVS SYSTEM CODES -S522

The wait time limit was exceeded for a job or job step.

1. The operator did not respond to a console request.
2. The program was waiting for a resource that was not available at execution time.
3. The CPU resource was not available at execution time.
4. The user request was invalid.

1. Check with the operator to determine if there were any outstanding requests for your job.
2. Check with the operator to determine if there were any problem jobs running at the same time as yours.

Ref: www.ibmmainframes.com

Monday, July 06, 2009

MVS SYSTEM CODES -S613

An error occurred in tape related input/output.

1. The JCL DD statement was incorrect.
2. An input/output error occurred in label processing.
3. The standard header labels were missing for an input data set.
4. There was a hardware malfunction.
An error occurred in tape positioning.
An error occurred in reading a tape label.
The tape label was invalid.
An error occurred in writing a tape label.
An error occurred in writing a tapemark after the header labels.

1. Verify that the JCL specifies the correct volume and device.
2. Verify that the volume contains standard labels.
3. Resubmit the job specifying a different volume or device

Ref: www.ibmmainframes.com

Saturday, June 20, 2009

Mainframe and Commonly used Dataset options in SAS

1) FIRSTOBS - Causes processing to begin at a specified observation.
Example : data new (firstobs = 30);

2)OBS - Causes processing to end with the nth observation.
Example : data new (obs = 30);

3)LABEL - Specifies the label for the data set. Example : data new (Label = ‘label for input dataset is not permanent’);

4)WHERE - Selects the observations that match the specified condition.
Example : data new (where = (age ge 45));

5)YEARCUTOFF option
This System option specifies the first year of a 100 year span used by Informats & functions.
Based on this, the century values of dates are determined by SAS system if the year is specified as a two digit year.

The default value is 1920.

If the yearcutoff option is set to 1950 then the value
09/18/49 with MMDDYY8. format will be read as 18th September 2049.
This does not have any effect on year specified in four digits

Monday, May 25, 2009

MVS SYSTEM CODES -S322

Description:

The time limit was exceeded for a job or job step.

Possible causes:

1. An endless loop occurred in the executing program.
2. The time parameter on the job card did not allow enough time for the job to complete.
3. The time parameter on the exec card did not allow enough time for the step to complete.
4. If the time parameter was not specified, the default time limit was exceeded.

Resolution:
1. Check for program errors, especially endless loops that cause the job or job step to exceed the time limit.
2. Verify that the time limits for the given job are realistic.
If necessary, specify a longer time in the time parameter, and rerun the job.

Ref: www.ibmmainframes.com

Friday, May 15, 2009

MVS SYSTEM CODES -S30A

Memory error
1. The EZTVFM file is not large enough for the report being generated.
2. You have a subscript or index that is going out-of-bounds on an table or occurs clause .
3. A file or table size is greater than the JCL/file LRECL.
4. DCB mismatch.



Ref: www.ibmmainframes.com

Saturday, May 09, 2009

MVS SYSTEM CODES -S413

An error occurred in opening either a direct access or a magnetic tape data set.
1. An input/output error occurred in processing a tape data set.
2. The specified data set could not be located.
3. The label or DCB parameters were incorrect.
4. A requested device was unavailable.


1. No unit was available for mounting the volume which contained the data set being opened.
2. The volume on the allocated unit (as specified by ser) could not be demounted because it was either reserved or permanently resident.

The volume serial number was not specified on the DD statement for a data set which was opened for input.
An invalid volume sequence number in the JCL specified a value greater than the number of volumes contained on the data set.
An error occurred while opening a magnetic tape data set.
The density specified in the DEN sub parameter was incompatible with the recording density of the device allocated.
An error was caused by a subsystem interface problem.
The mass storage system did not mount the requested volume.

Tape data set sequence number was specified greater than 1, but the volume serial number did not specify a tape data set.

1. Verify that the JCL is correct.
2. Rerun the job specifying a new volume or device.

Specify another device in the unit parameter of the DD statement. Determine how many volumes the data set spans, and request the appropriate volume.

Ref: www.ibmmainframes.com
Computers Add to Technorati Favorites Programming Blogs - BlogCatalog Blog Directory